CR019RW, Water/Glycol Cooled, 19kW
The Liebert CRV system offers highly flexible, in-row cooling for data centers requiring higher density cooling with greater efficiency and capacity. The system is designed for small and medium data centers or higher density containment applications in large data centers.
Guadar este produto no seu dashboard
Você pode guardar este produto no seu dashboard para ve-lo depois. Você pode elimina-lo com facilidade do seu dashboard quando você já no quer ve-lo lá.
Please login or create an account to save this for later
- Bancos, Setor Financeiro e Seguradoras
- Data Center/ Colocation / Hosting
- Educação
- Governo
- Setor de Saúde
- Varejista e Atacadista
CR019RW, Water/Glycol Cooled, 19kW
The Liebert CRV system offers highly flexible, in-row cooling for data centers requiring higher density cooling with greater efficiency and capacity. The system is designed for small and medium data centers or higher density containment applications in large data centers.
- Bancos, Setor Financeiro e Seguradoras
- Data Center/ Colocation / Hosting
- Educação
- Governo
- Setor de Saúde
- Varejista e Atacadista
Vantagens
Recursos
Especificações
The Liebert CRV is a precision data center cooling solution providing temperature and humidity control. It integrates within a row of data center racks, providing cooling close to the heat load. The Liebert CRV used with Liebert Optimized Aisle Controls independently manages airflow and temperature, greatly improving efficiency and supporting higher rack densities. Adjustable airflow baffles allow you to more precisely direct airflow within the row. Liebert CRV uses environmentally-friendly R410A refrigerant. The system is available in two widths, 300mm and 600mm, and multiple capacities. It is available in systems for air, water/glycol, and chilled water cooling.
- Product Specifications
- Total Nominal Capacity kBtuh [kW]
- 64.8 [19.0]
- Net Sensible Capacity kBtuh [kW]*
- 81.4 [23.9]
- Nominal Airflow [CFM]
- 2250 [3823]
- Total Capacity
- 82.5 [24.2]
- Airflow Direction
- Adjustable baffles
- Heat Rejection Medium
- Water/Glycol
- Capacity Modulation
- Variable Speed EC Fans
- Controls & Monitoring
- Liebert iCOM Unit Controls
- Physical Characteristics
- Peso (lbs / kgs)
- 544.54 (247)
- Altura (pol/mm)
- 78.74 (2000)
- Largura (pol/mm)
- 11.81 (300)
- Profundidade (pol/mm)
- 43.30 (1100)