NetSure 7100 Compact 582137100101-106 (19")
19" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 500 A at -48 VDC. High operating temperature (350A system rating at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
Guadar este produto no seu dashboard
Você pode guardar este produto no seu dashboard para ve-lo depois. Você pode elimina-lo com facilidade do seu dashboard quando você já no quer ve-lo lá.
Please login or create an account to save this for later
- Telecomunicação
NetSure 7100 Compact 582137100101-106 (19")
19" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 500 A at -48 VDC. High operating temperature (350A system rating at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
- Telecomunicação
Vantagens
Recursos
Especificações
- Product Overview
- Power Capacity
- 24 kW
- Current Capacity
- 500 A
- Output Voltage, Nominal
- -48 VDC
- Input Voltage, Nominal
- 100 to 240 VAC
- System Type
- Rack or cabinet mount
- Input
- Input Voltage, Nominal
- 100 to 240 VAC
- Input Voltage, Operational
- 120/208/240 VAC, single phase (operational)
- Input Connections
- Terminal block (up to 6 AWG) for individual rectifier feed
- Access
- Front and rear for installation, Front for operation and maintenance
- Output
- Output Voltage, Nominal
- -48 VDC
- Output Capacity
- 350 A @ +65 °C; 500 A @ +40 °C
- Load Circuit Breakers / Fuses
- (21) (6 on Load 1 bus, 6 on Load 2 bus, 9 on Priority bus)
- Physical Characteristics
- Peso (lbs / kgs)
- 19.1 to 24.5 kg
- Altura (pol/mm)
- 6-8U (266 to 347 mm)
- Largura (pol/mm)
- 483 mm
- Profundidade (pol/mm)
- 395 to 420 mm
- Environmetal & Standard Compliance
- Temperatura de Operação
- -40°C to +65°C (-40°F to +149°F)
- Safety Compliance
- UL 62368 Recognized
- Vertiv-Netsure-7100-Compact-500A-DS-EN-NA-DC-00114-WEB
- Vertiv™ NetSure™ NCU Controller Data Sheet
- Vertiv-eSure-Rectifier-R48-3500E3-DS-EN-GL-DC
- DAS-Solutions-BR-EN-NA-OE-00152
- PSD_Vertiv-NetSure-DC-Power-Services-Maintenance_NA-ENG_Datasheet
- PSD_Vertiv-NetSure-DC-Power-Services-Test-and-Turn-Up_NA-ENG_Datasheet
*Para ver downloads específicos de modelos, é necessário acessar a página de produto específica do modelo, selecionando o nome do modelo na tabela de especificações acima.