NetSure 7100 Compact 582127000600-901 (23")
23" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. High operating temperature (up to 900 amps at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
Guadar este produto no seu dashboard
Você pode guardar este produto no seu dashboard para ve-lo depois. Você pode elimina-lo com facilidade do seu dashboard quando você já no quer ve-lo lá.
Please login or create an account to save this for later
- Telecomunicação
NetSure 7100 Compact 582127000600-901 (23")
23" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. High operating temperature (up to 900 amps at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
- Telecomunicação
Vantagens
Recursos
Especificações
- Product Overview
- Power Capacity
- 28.8 too 43.2 kW
- Current Capacity
- 600 to 900 A
- Output Voltage, Nominal
- -48 VDC
- Input Voltage, Nominal
- 208 to 240 VAC
- System Type
- Cabinet mount
- Input
- Input Voltage, Nominal
- 208 to 240 VAC
- Input Voltage, Operational
- 120/208/240 VAC, single phase (operational)
- Output
- Output Voltage, Nominal
- -48 VDC
- Output Capacity
- 500 A @ +40 °C
- Load Circuit Breakers / Fuses
- (21) (6 on Load 1 bus, 6 on Load 2 bus, 9 on Priority bus)
- Physical Characteristics
- Peso (lbs / kgs)
- 56.7 to 62.6 kg
- Altura (pol/mm)
- 10-11U (444.5 to 489 mm)
- Largura (pol/mm)
- 584.2 mm
- Profundidade (pol/mm)
- 518.2 mm
- Environmetal & Standard Compliance
- Temperatura de Operação
- -40°C to +40°C (-40°F to +104°F)
- Safety Compliance
- UL 62368 Recognized
- um02440103-sm-io2-user-manual
- Vertiv™ Netsure™ 7100 -48V DC Power System Installation Manual IM582127000900.pdf
- UM1R483500E3 Rectifier User Manual
- UM60147273 eSure +27 VDC Bullet Converter Installation and User Manual
- DC Generator Input Landing Kit Installation Manual IM10067484.pdf
- DC Generator Input Circuit Breaker Kit Installation Manual IM60141027.pdf
- +27 VDC Vertiv™ eSure™ Bullet Converter Mounting Bracker Kit IM60171745.pdf
- UM10062803 +27 VDC Bullet Nose 6-Position GMT Fuse Board Kit Installation User Manual.pdf
*Para ver downloads específicos de modelos, é necessário acessar a página de produto específica do modelo, selecionando o nome do modelo na tabela de especificações acima.