CR019RW, Water/Glycol Cooled, 19kW
The Liebert CRV system offers highly flexible, in-row cooling for data centers requiring higher density cooling with greater efficiency and capacity. The system is designed for small and medium data centers or higher density containment applications in large data centers.
Se ha guardado este producto en su dashboard
Acaba de guardar este producto en su dashboard para verlo más tarde. Cuando ya no quiera tenerlo guardado, puede eliminar fácilmente el elemento de su dashboard.
Inicie sesión o cree una cuenta para guardar esto para más tarde
- Banca, finanzas y seguros
- Centro de datos/Coubicación/Hosting
- Educación
- Gobierno
- Salud
- Venta minorista y mayorista
CR019RW, Water/Glycol Cooled, 19kW
The Liebert CRV system offers highly flexible, in-row cooling for data centers requiring higher density cooling with greater efficiency and capacity. The system is designed for small and medium data centers or higher density containment applications in large data centers.
- Banca, finanzas y seguros
- Centro de datos/Coubicación/Hosting
- Educación
- Gobierno
- Salud
- Venta minorista y mayorista
Beneficios
Características
Especificaciones
The Liebert CRV is a precision data center cooling solution providing temperature and humidity control. It integrates within a row of data center racks, providing cooling close to the heat load. The Liebert CRV used with Liebert Optimized Aisle Controls independently manages airflow and temperature, greatly improving efficiency and supporting higher rack densities. Adjustable airflow baffles allow you to more precisely direct airflow within the row. Liebert CRV uses environmentally-friendly R410A refrigerant. The system is available in two widths, 300mm and 600mm, and multiple capacities. It is available in systems for air, water/glycol, and chilled water cooling.
- Product Specifications
- Capacidad nominal total en kBtuh [kW]
- 64.8 [19.0]
- Capacidad sensible neta en kBtuh [kW]*
- 81.4 [23.9]
- Flujo de aire nominal [CFM]
- 2250 (3823)
- Total Capacity
- 64.8 [19.0]
- Net Sensible Capacity
- 81.4 [23.9]
- Nominal Airflow
- 2250 [3823]
- Airflow Direction
- Adjustable baffles
- Heat Rejection Medium
- Water/Glycol
- Capacity Modulation
- Variable Speed EC Fans
- Controls & Monitoring
- Liebert iCOM Unit Controls
- Physical Characteristics
- Peso (lbs / kg)
- 544.54 (247)
- Alto (pulgadas / mm)
- 78.74 (2000)
- Ancho (pulgadas / mm)
- 11.81 (300)
- Fondo (pulgadas / mm)
- 43.30 (1100)
* Para ver descargas específicas de modelos, debe ir a la página de producto específica del modelo al seleccionar el nombre del modelo en el gráfico de especificaciones arriba.