NetSure 7100 Compact 582127000600-901 (23")
23" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. High operating temperature (up to 900 amps at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Telecom
NetSure 7100 Compact 582127000600-901 (23")
23" wide Vertiv™ NetSure™ 7100 Compact systems are designed for rapid deployment in telecom access network applications requiring a reliable and high density power supply up to 900 A at -48 VDC. High operating temperature (up to 900 amps at +65°C) coupled with high operational efficiency has a positive impact on climate system dimensioning in outdoor enclosure applications.
- Telecom
Benefits
Features
Specifications
- Product Overview
- Power Capacity
- 28.8 too 43.2 kW
- Current Capacity
- 600 to 900 A
- Output Voltage, Nominal
- -48 VDC
- Input Voltage, Nominal
- 208 to 240 VAC
- System Type
- Cabinet mount
- Input
- Input Voltage, Nominal
- 208 to 240 VAC
- Input Voltage, Operational
- 120/208/240 VAC, single phase (operational)
- Output
- Output Voltage, Nominal
- -48 VDC
- Output Capacity
- 500 A @ +40 °C
- Load Circuit Breakers / Fuses
- (21) (6 on Load 1 bus, 6 on Load 2 bus, 9 on Priority bus)
- Physical Characteristics
- Weight
- 56.7 to 62.6 kg
- Height
- 10-11U (444.5 to 489 mm)
- Width
- 584.2 mm
- Depth
- 518.2 mm
- Environmetal & Standard Compliance
- Operating Temperature
- -40°C to +40°C (-40°F to +104°F)
- Safety Compliance
- UL 62368 Recognized
- IM582127000600-901 (23") NetSure 7100 Compact Installation Manual
- UM1R483500E3 Rectifier User Manual
- UM60147273 eSure +27 VDC Bullet Converter Installation and User Manual
- UM582127000900 (Rev C)
- PSD_NetSure-Control-Unit_UM1M830BNA_NA-English_User-Manual
- PSD_eSure-Rectifier-Module_1R483500e3 _Global-English_User-Manual_Rev-L
- UM547490 SM-TEMP User Manual
- Vertiv-Netsure-7100-Compact-900A-DS-EN-NA-DC-00116-WEB
- Vertiv™ NetSure™ NCU Controller Data Sheet
- Vertiv-eSure-Rectifier-R48-3500E3-DS-EN-GL-DC
- DAS-Solutions-BR-EN-NA-OE-00152
- PSD_Vertiv-NetSure-DC-Power-Services-Maintenance_NA-ENG_Datasheet
- PSD_Vertiv-NetSure-DC-Power-Services-Test-and-Turn-Up_NA-ENG_Datasheet
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.