PX011, 11kW
The Liebert PDX direct expansion cooling system offers the industry’s highest efficiency, protection and capacity per footprint for server room cooling. network closets and other small spaces.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
PX011, 11kW
The Liebert PDX direct expansion cooling system offers the industry’s highest efficiency, protection and capacity per footprint for server room cooling. network closets and other small spaces.
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
Benefits
Features
Industry’s highest capacity per footprint
Specifications
The Liebert PDX is highly configurable and available in a wide range of capacities. Available cooling types available include Air; Water/Glycol; Dual Cooling (Water/ Glycol Cooled + Econ-O-Coil), providing full and partial free cooling; Dual Cooling (Chilled Water + Air-Cooled Refrigeration), providing full and partial free cooling; and GLYCOOL™ (Fluid-cooled Economizer and DX Refrigeration System). The units feature variable speed EC fans that reduce motor energy usage up to 80%, compared to standard AC motors, and are more efficient than centrifugal blowers even when operating at 100% fan speed. The digital scroll compressor in the Liebert PDX uses R-410A refrigerant. Condensers on the water/glycol cooled, dual-cooling, and GLYCOOL systems feature motorized control valves, managed by the Liebert iCOM controls. These valves control the water or water/glycol flow and maintain the desired condensing temperature for various entering fluid temperatures. The Liebert PDX offers unique, floor-level air discharge that reduces the mixing of hot and cold air to improve efficiency. Downflow models provide front, left side and right side discharge and upflow models provide front and rear return options.
- Product Specifications
- Total Nominal Capacity kBtuh [kW]
- 37.5 [11]
- Net Sensible Capacity kBtuh [kW]
- 32.4 [9.5]
- Nominal Airflow [CFM]
- 1800
- Total Capacity
- 35.8 [10.5]
- Airflow Direction
- Upflow and Downflow
- Heat Rejection Medium
- R-410A Refrigerant
- Capacity Modulation
- Variable speed EC fans
- Controls and Monitoring
- Liebert iCOM Unit Control
- Physical Characteristics
- Weight
- 600
- Weight
- 272
- Height
- 77 9/16
- Height
- 1970
- Width
- 34 1/2
- Width
- 876
- Depth
- 34 5/8
- Depth
- 879
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.