CRD101, Air-Cooled, 300mm, 10kW, 208-230V/3PH/60Hz
The Liebert® CRV 10kW is the next generation in row-based server rack cooling designed specifically for edge applications. It delivers up to 10kW of scalable cooling capacity in a minimal footprint, allowing the user to match changing IT heat loads. The variable-speed compressor and fans drive efficiency and scalability while the dual power supply and Liebert® iCOM™ Edge Controls ensure high cooling availability and reliability for your critical IT equipment.
Saved This Product to Your Dashboard
You just saved this product to your dashboard to view at a later time. You can easily remove the item from your dashboard when you no longer wish to have it saved.
Please login or create an account to save this for later
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
CRD101, Air-Cooled, 300mm, 10kW, 208-230V/3PH/60Hz
The Liebert® CRV 10kW is the next generation in row-based server rack cooling designed specifically for edge applications. It delivers up to 10kW of scalable cooling capacity in a minimal footprint, allowing the user to match changing IT heat loads. The variable-speed compressor and fans drive efficiency and scalability while the dual power supply and Liebert® iCOM™ Edge Controls ensure high cooling availability and reliability for your critical IT equipment.
- Banking, Financial and Insurance
- Data Center/Colocation/Hosting
- Education
- Government
- Healthcare
- Retail and Wholesale
Specifications
In edge environments where space is at a premium and energy costs must remain low, the Liebert® CRV 10kW delivers scalable cooling capacity in a minimal footprint to give you greater flexibility and efficiency to meet your small data center cooling challenges. Available with a single-phase voltage option, the in-row cooling system fits seamlessly into any small IT space with a “hot-aisle/cold-aisle” configuration, including raised floor and non-raised floor applications. The compact unit can be placed between racks or at the end of the row, bringing cooling closer to the heat source, and it uses adjustable air discharge baffles to direct supply air flow wherever it is needed. Load matching controls and EC fans further increase efficiency, offering scalable data center cooling capacity down to 2kW. Power supply redundancy ensures critical system availability while the advanced Liebert® iCOM™ Edge Controls automatically adjust to optimize performance and energy efficiency around the clock. With the Liebert CRV 10kW, it’s easy and efficient to protect critical IT equipment in edge applications, server rooms, and small data centers.
- Product Specifications
- Total Nominal Capacity kBtuh [kW]
- 35.8 [10.5]
- Net Sensible Capacity kBtuh [kW]*
- 34.1 [10]
- Nominal Airflow [CFM]
- 1960 [3030]
- Total Capacity
- 10.5 kW
- Net Sensible Capacity
- 10kW
- Input Voltage (V/Phase/Frequency Hz)
- 208-230V / 3Ph / 60Hz
- Nominal Airflow
- 1960 CFM
- Airflow Direction
- Horizontal
- Heat Rejection Medium
- R410A Refrigerant
- Capacity Modulation
- 20-100%
- Controls & Monitoring
- iCOM™ Edge & Unity Card
- Agency Approvals
- UL
- Key Components
- Inverter Driven Compressor, EC Fans, iCOM™ Edge Controller, EEV
- Key Options
- Dual Power Supply, Air Discharge Baffles, SNMP, HTTP, Modbus and Bacnet monitoring protocols
- Allowable Heat Rejection
- Air Cooled Condenser CCD100S-00A
- Physical Characteristics
- Weight
- 509.27 (231)
- Height
- 78.74 (2000)
- Width
- 11.81 (300)
- Depth
- 44.57 (1132)
*To see model-specific downloads, you will need to go to the model-specific product page by selecting the model name in the specifications chart above.